Copier D014/D015/D078/D079
D014/D015/D078/D079 1-20 SM
6. Confirm that the neck of each bottle snaps and locks in place. Confirm that the neck of
each bottle is parallel with the top of each PCU.
7. To prevent the bottle from falling off, hold the bottle [B] with the left hand as shown, pull
the heat seal [A] out of the developer bottle and remove it.
8. Pull the seals from all of the bottles (Y, C, M, K).
9. Make sure that you have removed all the seal strips (you should have four strips, one
for each bottle).
10. Gently tap the sides of each bottle to make sure that the developer flows freely.
11. Close the front door.
The door must be closed before you switch the machine on.
12. Turn the machine power on.
13. Enter the SP mode and do the following SPs:
SP3814-1. Fills all of the PCU units with developer from the attached bottles. It
takes about 4 minutes. Press 'Exit' when 'Completed' appears on the display.
SP3815. Confirms that SP3814-1 executed correctly. If SP3814-1 executed
correctly, you will see "1111" (K M C Y).
OK
NG
Make sure the neck of
the bottle snaps and
locks into place.
Make sure there is no gap
between the developer bottle
and PCU.
⇒
Rev. 02/2008
[B]
[A]