PCU
SM 3-61 D014/D015/D078/D079
Replacement
Adjustment
5.
6. Execute the SP codes described on the guide sheet.
Four SP codes must be set for the new PCU.
Execute only the SP codes where the sticker is attached (removed and attached to
the guide sheet).
Do not execute any other SP codes on this sheet.
If you replace only the development unit, you must also do these SP modes.
7. Add developer to the new PCU.
Do SP3010, 3011, 3012, or 3013 before you initialize the developer.