Service Call Tables
SM 4-39 D014/D015/D078/D079
Trouble-
shooting
Fusing cooling fan error
SC530 B
The VBCU did not receive the
lock signal 5 seconds after the
fusing unit fan switches on.
Fan harness disconnected or
damaged
Fan blocked by an obstruction
Fan damaged
Fusing Fan Error: Front
SC531 B
The lock signal remained
HIGH for 5 sec. while the fan
at the front of the fusing unit
near the heat dissipation fins
was operating.
Fan harness disconnected or
damaged
Fan blocked by an obstruction
Fan damaged
Controller fan error
SC532 B
The lock signal remained
HIGH for 5 sec. while the
fan that cools the printed
circuit boards was
operating.
Fan harness disconnected or damaged
Fan blocked by an obstruction
Fan damaged
Fusing unit suction fan error
SC533 B
The lock signal remained
HIGH for 5 sec. while the
fan that draws air out of the
fusing unit was operating.
Fan harness disconnected or damaged
Fan blocked by an obstruction
Fan damaged
Duplex unit fan error
SC534 B
The lock signal remained
HIGH for 5 sec. while the
fan that draws air out of the
duplex unit was operating.
Fan harness disconnected or damaged
Fan blocked by an obstruction
Fan damaged
Rev. 07/30/2009
NOTE: The fans described in SC534 are the Front Duplex and
Rear Duplex Fan Motors. Refer to the D014/D015
Electrical Motor Layout 2/3 Symbols M29 and M30.
⇒