Service Call Tables
D014/D015/D078/D079 4-72 SM
Self-diagnostic error 1: ASIC *GW
The ASIC provides the central point for the control of bus arbitration for
CPU access, for option bus and SDRAM access, for SDRAM refresh,
and for management of the internal bus gate.
0B00
Error code 0xffff ffff is returned
when the register Write &
Verify check is executed on
the ASIC mounted on the
controller board. The ASIC
controls the ROM and buses
for other devices.
ASIC (controller board
defective)
0B06 ASIC not detected
ASIC (controller board
defective)
Poor connection between
North Bridge and PCI I/F:
Replace controller board
SC821 C
0B10
Failed to initialize or could not
read connection bus. Data in
SHM register incorrect.
Replace controller board
Note: For more details about this SC code error, execute SP5990 to print an SMC report so
you can read the error code. The error code is not displayed on the operation panel.