Group 2000
SM 5-91 D014/D015/D078/D079
Service
Tables
2911 Environ Ctrl
These SP codes control the operation of the Peltier unit.
Note: The Peltier unit is not provided as a standard component of this machine.
However, it is available as an option.
1 Environ Ctrl On
Switches Peltier unit control on/off.
*OFF/ON
4 Op Humidity
Sets the humidity level for the Peltier unit to operate.
[0 to 100/60/1%]
5 Stop Humidity
Sets the humidity level for the Peltier unit to switch off.
[0 to 100/35/1%]
6 Op On Time
Sets the timer for the humidity level for the Peltier unit to
switch on, regardless of the humidity level control
settings done with SP2911-4, -5.
[1 to 60/10/1 min.]
7 Op Off Time
Sets the timer for the humidity level for the Peltier unit to
switch off, regardless of the humidity level done with
SP2911-4, -5.
[1 to 60/5/1 min.
2912 Encoder Sn:Adj Light
1 Adj Light Amt
2 Light Amt Adj:Pass/Fail
3 Vref_Disp:Main Setting
4 Vref_Disp:Sub Setting
5 Analog Out:Main:After F Adj
6 Analog Out:Sub:After F Adj
7 Light Amt Change Flag