Group 2000
D014/D015/D078/D079 5-90 SM
7 Set Execute Interval
Sets the distance interval between motor
reverse executions during continuous print jobs.
[1 to 500/ 1 m] Default: 250 m
8 Op Time Setting:Bk
Sets the length of time for the K PCU drum
motor to reverse.
[2 to 500/30/2 msec]
9 Op Time Setting:YCM
Sets the length of time for the YMC PCU drum
motors to reverse.
[2 to 500/30/2 msec]
10 Op Time Setting:ImgTrans
Sets the length of time for the ITB motor
to reverse.
[2 to 500/30/2 msec]
11 Op Time Setting:PaperTrans
Sets the length of time for the PTR motor
to reverse.
[2 to 500/30/2 msec]
12 Adj Reverse Start Time
Synchronizes the timing for the K PCU drum
motor, ITB motor and PTR motor to reverse
simultaneously.
[2 to 500/0/2 msec]
2907
PTR Lift DFU
This SP switches the operation of the PTR lift motor off and on. The PTR lift motor
presses the PTR against the fusing belt above during belt-to-paper image transfer
and lowers the PTR when it is idle. This prevents the PTR from warping.
[*0: Lift Operation On]
[1: Lift Operation Off]