Group 2000
SM 5-89 D014/D015/D078/D079
Service
Tables
2905 Used Toner Mtr 2 Used Toner Motor 2 Control
The used toner bottle is provided with a near-full sensor and an auger that
evenly distributes the used toner inside the bottle. To extend the life of the used
toner bottle near-full motor that rotates this auger, the motor and auger do not
operate continuously. The motor is turned on only after a prescribed amount of
toner has been consumed.
1 Tnr Consumed
Sets the amount of toner to be consumed before the used
toner bottle is switched on.
[1 to 10/1 g]
2 Tnr Mtr On Time
Sets the amount of time the motor remains on.
[1 to 10/1 sec.]
2906 Stop Time Reverse Ctrl
The K drum motor, YMC drum motor, ITB motor, and PTR motor can be set to
reverse slightly immediately after they stop. This removes dust from the edges of
the cleaning blades. These SP codes:
Switch this feature on/off (Default: OFF)
Set the absolute intervals (distance) for execution of stop/reverse timing
Set the intervals (distance) for execution of stop/reverse timing during long
print jobs.
1 Set Rev Execute:K
2 Set Rev Execute:YCM
3 Set Rev Execute:ImgTrans
4 Set Rev Execute:PaperTrans
These SP codes switch on/off the stop/reverse
feature for the K PCU drum motor, YMC PCU
drum motor, ITB motor, and PTR motor.
Default: Off
5 Set Rev Execute Interval
Sets the distance interval between motor
stop/reverse executions.
[1 to 500/ 1 m] Default: 30 m
6 Assign Execution
Switches on the time interval that controls motor
reverse executions during continuous print jobs.