Group 4000
SM 5-153 D014/D015/D078/D079
Service
Tables
4907 Set SBU Test Pattern
This SP selects the pattern generated by the SBU.
[*0: Normal Scanner Output]
[1: Fixed Value Output]
[2: Main Scan Grayscale Output]
[3: Sub Scan Grayscale Output]
[4: Grid Output]
4918
Man Gamma Adj DFU
4948 ACC Execute Time:Present
1 yy/mm/dd
2 hh/mm/ss
4949
ACC Execute Time:Previous DFU
4954 Read/Restore Std
Use this SP to calibrate the scanner gamma on each machine connected with the
Copier Connection Kit.
1 Read New Chart
Reads the "Standard Color Test Chart" to calibrate
the scanner gamma curve for two machines
connected with the Copier Connection Kit. Do this
SP with the test chart on each connected machine.
2 Recall Prev Chart
Restores the scanner gamma to the previous value
(not the factory setting).
3 Read Std. Chart
4 Set Std Chart