Group 5000
D014/D015/D078/D079 5-194 SM
Line type Automatic Judgment
151
Press [Execute].
Setting this SP classifies the telephone line where embedded RCG-M is
connected as either dial-up (pulse dial) or push (DTMF tone) type, so embedded
RCG-M can automatically distinguish the number that connects to the outside
line.
The current progress, success, or failure of this execution can be displayed
with SP5816-152.
If the execution succeeded, SP5816-153 will display the result for
confirmation and SP5816-154 will display the telephone number for the
connection to the outside line.
Line type Judgment Result
152
Displays a number to show the result of the execution of SP5816-151. Here is a
list of what the numbers mean.
0: Success
1: In progress (no result yet). Please wait.
2: Line abnormal
3: Cannot detect dial tone automatically
4: Line is disconnected
5: Insufficient electrical power supply
6: Line classification not supported
7: Error because fax transmission in progress – ioctl() occurred.
8: Other error occurred
9: Line classification still in progress. Please wait.
Selection Dial/push
153
This SP displays the classification (tone or pulse) of the telephone line to the
access point for embedded RCG-M. The number displayed (0 or 1) is the result
of the execution of SP5816-151. However, this setting can also be changed
manually.
[0 to 1 / 0 / 1 /step]
0: Tone Dialing Phone
1: Pulse Dialing Phone
CÓPIA NÃO CONTROLADA