Group 5000
SM 5-197 D014/D015/D078/D079
Service
Tables
Modem serial No.
173
This SP displays the serial number registered for the embedded RCG-M.
Retransmission Limit
174
Normally, it is best to allow unlimited time for certification and ID2 update
requests, and for the notification that the certification has been completed.
However, embedded RCGM generates charges based on transmission time for
the customer, so a limit is placed upon the time allowed for these transactions.
If these transactions cannot be completed within the allowed time, do this SP to
cancel the time restriction.
RCG - C M Debug Bit SW
186
FAX TX Priority
187
This SP determines whether pushing the off-hook button will interrupt an
embedded RCGM transmission in progress to open the line for fax transaction.
This SP can be used only if SP5816-164 is set to "0".
[0 or 1/ 0 / - ]
0: Disable. Setting the fax unit off-hook does not interrupt a fax transaction in
progress. If the off-hook button is pushed during a embedded RCG-M
transmission, the button must be pushed again to set the fax unit on-hook after
the embedded RCG-M transmission has completed.
1: Enable. When embedded RCG-M shares a line with a fax unit, setting the fax
unit off-hook will interrupt a embedded RCG-M transmission in progress and
open the line for a fax transaction.
Manual Polling
200
No information is available at this time.
Regist: Status
Displays a number that indicates the status of the @Remote service device.
201
0
Neither the registered device by the external nor embedded RCG device
is set.