Command reference
R&S
®
ZNB/ZNBT
1027User Manual 1173.9163.02 ─ 62
CALCulate<Ch>:TRANsform:VNETworks:DIFFerential:EMBedding<LogPt>:
PARameters:L<Cmp> <CircuitModel>[, <Inductance>]
Specifies the inductance value L in the "Shunt L, Shunt C" lumped element model for
differential match embedding.
In the query form, the <Inductance> parameter must be omitted.
Suffix:
<Ch>
.
Channel number
<LogPt> Logical port number (balanced port)
<Cmp> Must be omitted or set to 1
Parameters:
<CircuitModel> SHLC
Currently only the "Shunt L, Shunt C" lumped element model is
supported
<Inductance> Range: -1 H to 1 H
Increment: 1 pH (1E-12 H)
*RST: 1 nH (1E-9 H)
Default unit: H
Manual operation: See "Network" on page 650
CALCulate<Ch>:TRANsform:VNETworks:DIFFerential:EMBedding<LogPt>:
PARameters:R<Cmp> <CircuitModel>[, <Resistance>]
Specifies the resistance value R in the "Shunt L, Shunt C" lumped element model for
differential match embedding.
In the query form, the <Resistance> parameter must be omitted.
Suffix:
<Ch>
.
Channel number
<LogPt> Logical port number (balanced port)
<Cmp> Must be omitted or set to 1.
Parameters:
<CircuitModel> SHLC
Currently only the "Shunt L, Shunt C" lumped element model is
supported
<Resistance> Range: -10 MΩ to 10 MΩ.
Increment: 1 mΩ (1E-3 Ω)
*RST: 0 Ω
Default unit: Ohm
Manual operation: See "Network" on page 650
SCPI command reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNB Series and is the answer not in the manual?

R&S ZNB Series Specifications

General IconGeneral
BrandR&S
ModelZNB Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals