Command reference
R&S
®
ZNB/ZNBT
1305User Manual 1173.9163.02 ─ 62
Example:
SEGM1:DEF:SEL DWEL
Select the measurement delay to determine the sweep time in a
new sweep segment no. 1.
SEGM1:DEF 1MHZ, 1.5MHZ, 111, -21DBM, 0.01S, 0,
10KHZ
Create a sweep segment with a sweep range between 1.0 MHz
and 1.5 MHz and a measurement delay of 10 ms.
SEGM1:SWE:TIME?
Query the sweep time in the new segment.
Manual operation: See "Optional Columns" on page 435
[SENSe<Ch>:]SEGMent<Seg>:DELete:ALL
Deletes all sweep segments in the channel. [SENSe<Ch>:]SEGMent<Seg>:
DELete[:DUMMy] deletes a single segment.
Suffix:
<Ch>
.
Channel number
<Seg> Sweep segment number. This suffix is ignored; the command
deletes all segments.
Example:
SEGM:ADD
Create a new sweep segment no. 1 in channel no. 1 using
default settings.
SEGM:DEL:ALL
Delete the created segment and all segments in the channel cre-
ated before.
Usage: Event
Manual operation: See "Add / Insert / Delete / Delete All" on page 433
[SENSe<Ch>:]SEGMent<Seg>:DELete[:DUMMy]
Deletes the specified (single) sweep segment. [SENSe<Ch>:]SEGMent<Seg>:
DELete:ALL deletes all segments in the channel.
Suffix:
<Ch>
.
Channel number
<Seg> Sweep segment number
Example:
SEGM:ADD
Create a new sweep segment no. 1 in channel no. 1 using
default settings.
SEGM:DEL
Delete the created segment.
Manual operation: See "Add / Insert / Delete / Delete All" on page 433