Command reference
R&S
®
ZNB/ZNBT
1456User Manual 1173.9163.02 ─ 62
DIAGnostic:HUMS:UTILization:ACTivity:TRACking:STATe <ID>, <State>
DIAGnostic:HUMS:UTILization:ACTivity:TRACking:STATe? <ID>
Turns the activity tracking of utilizations on and off.
Parameters:
<State> ON | OFF | 1 | 0
ON | 1
Tracking activity = on
OFF | 0
Tracking activity = off
Parameters for setting and query:
<ID> ID number of the utilization activity.
To find out the ID of the utilization, you have to query the com-
plete utilization data. For more information, see DIAGnostic:
HUMS:UTILization? on page 1455.
Example: //Set activity tracking state of ID 31719936
DIAG:HUMS:UTIL:ACT:TRAC:STAT 31719936,'1'
DIAGnostic:HUMS:UTILization:CUSTom:ADD <ID>, <Name>, <Description>,
<Unit>, <State>
Creates a custom utilization.
Setting parameters:
<ID> Identifier of the custom utilization.
Range: 1 to 99
<Name> Name of the custom utilization that appears in the user interface.
<Description> Description of the custom utilization.
<Unit> Unit of the custom utilization that appears in the user interface.
<State> ON | OFF | 1 | 0
Initial activity state of custom utilization.
HUMS and service date commands