Command reference
R&S
®
ZNB/ZNBT
869User Manual 1173.9163.02 ─ 62
Manual operation: See "Active" on page 699
CALCulate<Chn>:EYE:JITTer:TYPE:DIRac <Boolean>
Enables/disables Dirac jitter insertion in the generator simulation of the related eye dia-
gram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Amplitude and probability of the jitter can be specified using CALCulate<Chn>:EYE:
JITTer:DIRac:DELTa and CALCulate<Chn>:EYE:JITTer:DIRac:
PROBability, respectively.
Note that jitter will not be applied unless the jitter functionality is activated using
CALCulate<Chn>:EYE:JITTer:STATe.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean> *RST: OFF
Options: R&S ZNB/ZNBT-K20
Manual operation: See "Dirac" on page 700
CALCulate<Chn>:EYE:JITTer:TYPE:PERiodic <Boolean>
Enables/disables periodic jitter insertion in the generator simulation of the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Amplitude, frequency and phase of the jitter can be specified using
CALCulate<Chn>:EYE:JITTer:PERiodic:MAGNitude, CALCulate<Chn>:EYE:
JITTer:PERiodic:FREQuency and CALCulate<Chn>:EYE:JITTer:PERiodic:
PHASe, respectively.
Note that jitter will not be applied unless the jitter functionality is activated using
CALCulate<Chn>:EYE:JITTer:STATe.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<Boolean> *RST: OFF
Options: R&S ZNB/ZNBT-K20
Manual operation: See "Periodic" on page 699