Group 5000
SM 5-187 D014/D015/D078/D079
Service
Tables
5812 Service Tel. No. Setting
1 Service
Inputs the telephone number of the CE (displayed when a
service call condition occurs.)
2 Facsimile
Use this to input the fax number of the CE printed on the Counter
Report (UP mode). Not Used
3 Supply Displayed on the initial SP screen.
4 Operation
Allows the service center contact telephone number to be
displayed on the initial screen.
5816 Remote Service
1 I/F Setting
Turns the remote diagnostics off and on.
[0 to 2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
2 CE Call
Lets the customer engineer start or end the remote
machine check with CSS or NRS; to do this, push the
center report key.
3 Function Flag
Enables and disables remote diagnosis over the NRS
network.
[0 to 1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
6
Device
Information Call
Display
Controls if the item for initial setting of the screen for the
NRS device-information notification-call is shown.
[0 to 1/1]
0: Enabled. Item initial setting not shown.
1: Disable. Item for initial setting shown.
CÓPIA NÃO CONTROLADA