Group 5000
D014/D015/D078/D079 5-188 SM
7 SSL Disable
Controls if RCG (Remote Communication Gate)
confirmation is done by SSL during an RCG send for the
NRS over a network interface.
[0 to 1/1]
0: Yes. SSL not used.
1: No. SSL used.
8
RCG Connect
Timeout
Sets the length of time (seconds) for the time-out when the
RCG (Remote Communication Gate) connects during a call
via the NRS network.
[1 to 90/1 sec.]
9
RCG Write to
Timeout
Sets the length of time (seconds) for the time-out when sent
data is written to the RCG during a call over the NRS
network.
[0 to 100/1 sec.]
010
RCG Read
Timeout
Sets the length of time (seconds) for the timeout when sent
data is written from the RCG during a call over the NRS
network.
[0 to 100/1 sec.]
011 Port 80 Enable
Controls if permission is given to get access to the SOAP
method over Port 80 on the NRS network.
[0 to 1/1]
0: No. Access denied
1: Yes. Access granted.