Command reference
R&S
®
ZNB/ZNBT
1075User Manual 1173.9163.02 ─ 62
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:LOW......................................................1089
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk.......................................................................1090
CONTrol<Ch>:RFFE<Bus>:TEST:DATA......................................................................... 1090
CONTrol<Ch>:RFFE<Bus>:TEST:VIO............................................................................1090
CONTrol:RFFE<Bus>:TEST:CLOCk:CURRent?.............................................................. 1091
CONTrol:RFFE<Bus>:TEST:DATA:CURRent?................................................................ 1091
CONTrol:RFFE<Bus>:TEST:VIO:CURRent?................................................................... 1091
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:RANGe...........................................................1091
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:RANGe............................................................. 1091
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:RANGe................................................................1091
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:SHUNt?..........................................................1091
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:SHUNt?............................................................ 1091
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:SHUNt?...............................................................1091
CONTrol:RFFE<Bus>:TEST:CLOCk:VOLTage?...............................................................1092
CONTrol:RFFE<Bus>:TEST:DATA:VOLTage?................................................................. 1092
CONTrol:RFFE<Bus>:TEST:VIO:VOLTage?....................................................................1092
CONTrol<Ch>:RFFE:TEST:OUTPut...............................................................................1092
CONTrol<Ch>:RFFE:TEST:SENSe:TRIGger...................................................................1093
CONTrol<Ch>:RFFE:TEST:TIME...................................................................................1093
CONTrol<Ch>:SEGMent<Nr>:DELay.............................................................................1093
CONTrol<Ch>:SEGMent<Nr>:GPIO<Port>:VOLTage.......................................................1094
CONTrol<Ch>:SEGMent<Nr>:RFFE<Bus>:COMMand:DATA........................................... 1094
CONTrol<Ch>:SEGMent<Nr>:SEQuence:CLEar:ALL...................................................... 1095
CONTrol<Ch>:SEGMent<Nr>:SEQuence:COUNt?..........................................................1095
CONTrol<Ch>:SEQuence:CLEar:ALL............................................................................ 1095
CONTrol<Ch>:SEQuence:COUNt?................................................................................1095
CONTrol<Ch>:SEQuence<Nr>:DELay........................................................................... 1096
CONTrol<Ch>:SEQuence<Nr>:GPIO<Port>:VOLTage..................................................... 1096
CONTrol<Ch>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA..........................................1097
CONTrol:AUXiliary:C[:DATA] <DecValue>
Sets or queries a channel-dependent eight-bit decimal value to control eight independ-
ent output signals at the User Port connector (lines 8, 9, 10, 11 and lines 16, 17, 18,
19). The output signals are 3.3 V TTL signals which can be used to differentiate
between up to 255 independent analyzer states. CONTrol:AUXiliary:C[:DATA]
itself does not change the analyzer state.
Channel bit definition and activation
The channel bits have the following properties:
After a *RST of the analyzer all channel bits (including the value for the active,
sweeping channel no. 1) are set to zero; no signal is applied to pins 8 to 11 and 16
to 19 of the User Port connector.
The value defined with CONTrol:AUXiliary:C[:DATA] is assigned to the
active channel (INSTrument:NSELect <Ch>).
The signals at the User Port connector reflect the channel bits of the measuring
channel, i.e. the channel for which the analyzer performs a sweep. This channel is
not necessarily identical with the active channel.