Chapter 4: Utility Commands 189
The following shows example CLI display output for the command.
(CN1610) #show environment
Temp (C)....................................... 36
Fan Speed, RPM................................. 12840
Fan Duty Level................................. 100%
Temperature traps range: 0 to 60 degrees (Celsius)
Temperature Sensors:
Unit Sensor Description Temp (C) State
Max_Temp (C)
---- ------ ---------------- ---------- ----------- -------
1 1 CPU & SWITCH 33 Normal 33
1 2 Left PHY's 34 Normal 35
1 3 Right PHY's 36 Normal 37
Fans:
Unit Fan Description Type Speed Duty level State
---- --- ----------- -------- ----- ------------- -----------
1 1 Fan-1 Removable 12840 100% Operational
1 2 Fan-2 Removable 12600 100% Operational
1 3 Fan-3 Removable 12660 100% Operational
1 4 Fan-4 Removable 12660 100% Operational
Power Modules:
Unit Power supply Description Type State
---- ------------ ---------------- ---------- -----------
1 1 Internal AC-1 Removable Operational
1 2 Internal AC-2 Removable Not powered
show hardware This command displays inventory information for the switch.
Power Supply The number of the power supply in the unit.
Description A description of the power module.
Type The type of power module.
State The current state of the power module.
Term Definition
Format
show hardware

Table of Contents