408 Port-Based Network Access Control Commands
no dot1x system-
auth-control
monitor
This command disables the 802.1X Monitor mode on the switch.
dot1x timeout This command sets the value, in seconds, of the timer used by the authenticator
state machine on an interface or range of interfaces. Depending on the token used
and the value (in seconds) passed, various timeout configurable parameters are
set. The following tokens are supported:
Mode Global Config
Format
no dot1x system-auth-control monitor
Mode Global Config
Tokens Definition
guest-vlan-period The time, in seconds, for which the authenticator
waits to see if any EAPOL packets are received on a
port before authorizing the port and placing the port
in the guest vlan (if configured). The guest vlan
timer is only relevant when guest vlan has been
configured on that specific port.
reauth-period The value, in seconds, of the timer used by the
authenticator state machine on this port to determine
when reauthentication of the supplicant takes place.
The reauth-period must be a value in the range 1 -
65535.
quiet-period The value, in seconds, of the timer used by the
authenticator state machine on this port to define
periods of time in which it will not attempt to
acquire a supplicant. The quiet-period must be a
value in the range 0 - 65535.

Table of Contents