Chapter 3: Management Commands 93
no snmp trap link-
status all
This command disables link status traps for all interfaces.
Note
This command is valid only when the Link Up/Down Flag is enabled. See “snmp
trap link-status” on page 92.
snmp-server enable
traps linkmode
This command enables Link Up/Down traps for the entire switch. When enabled,
link traps are sent only if the Link Trap flag setting associated with the port is
enabled. See “snmp trap link-status” on page 92.
no snmp-server
enable traps
linkmode
This command disables Link Up/Down traps for the entire switch.
snmp-server enable
traps multiusers
This command enables Multiple User traps. When the traps are enabled, a
Multiple User Trap is sent when a user logs in to the terminal interface (EIA 232
or Telnet) and there is an existing terminal interface session.
Format
no snmp trap link-status all
Mode Global Config
Default enabled
Format
snmp-server enable traps linkmode
Mode Global Config
Format
no snmp-server enable traps linkmode
Mode Global Config
Default enabled
Format
snmp-server enable traps multiusers
Mode Global Config