Chapter 4: Utility Commands 291
The following shows an example of the command.
(CN1610) (Interface 1/0/1-1/0/10)#rmon collection history 1 buckets
10 interval 30 owner myOwner
Error: 'rmon collection history' is not supported on range of
interfaces.
no rmon collection
history
This command will delete the history control group entry with the specified index
number.
The following shows an example of the command.
(CN1610) (Interface 1/0/1-1/0/10)# no rmon collection history 1
show rmon This command displays the entries in the RMON alarm table.
Format
no rmon collection history index number
Mode Interface Config
Format
show rmon {alarms | alarm alarm-index}
Mode Privileged EXEC
Parameter Description
Alarm Index An index that uniquely identifies an entry in the
alarm table. Each entry defines a diagnostic sample
at a particular interval for an object on the device.
The range is 1 to 65535.
Alarm Variable The object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1
primitive type of integer.
Alarm Interval The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. The range is 1 to 2147483647. The
default is 1.