Chapter 5: Switching Commands 549
lldp notification-
interval
Use this command to configure how frequently the system sends remote data
change notifications. The
interval parameter is the number of seconds to wait
between sending notifications. The valid interval range is 5-3600 seconds.
no lldp notification-
interval
Use this command to return the notification interval to the default value.
clear lldp statistics Use this command to reset all LLDP statistics, including MED-related
information.
clear lldp remote-
data
Use this command to delete all information from the LLDP remote data table,
including MED-related information.
Format
no lldp notification
Mode Interface Config
Default 5
Format
lldp notification-interval
interval
Mode Global Config
Format
no lldp notification-interval
Mode Global Config
Format
clear lldp statistics
Mode Privileged EXEC
Format
clear lldp remote-data
Mode Global Config