Chapter 5: Switching Commands 547
lldp timers Use this command to set the timing parameters for local data transmission on
ports enabled for LLDP. The
interval-seconds determines the number of
seconds to wait between transmitting local data LLDPDUs. The range is 1-32768
seconds. The
hold-value is the multiplier on the transmit interval that sets the
TTL in local data LLDPDUs. The multiplier range is 2-10. The
reinit-
seconds is the delay before reinitialization, and the range is 1-0 seconds.
no lldp timers Use this command to return any or all timing parameters for local data
transmission on ports enabled for LLDP to the default values.
lldp transmit-tlv Use this command to specify which optional type length values (TLVs) in the
802.1AB basic management set are transmitted in the LLDPDUs from an
interface or range of interfaces. Use
sys-name to transmit the system name
TLV. To configure the system name, see “snmp-server” on page 89. Use
sys-
desc
to transmit the system description TLV. Use sys-cap to transmit the
system capabilities TLV. Use
port-desc to transmit the port description TLV.
To configure the port description, see “description” on page 310
.
Mode Interface Config
Default ◆ interval—30 seconds
◆ hold—4
◆ reinit—2 seconds
Format
lldp timers
[interval
interval-seconds
] [hold
hold-
value
] [reinit
reinit-seconds
]
Mode Global Config
Format
no lldp timers [interval] [hold] [reinit]
Mode Global Config
Default no optional TLVs are included
Format
lldp transmit-tlv [sys-desc] [sys-name] [sys-cap]
[port-desc]
Mode Interface Config