Chapter 5: Switching Commands 553
The following shows example CLI display output for the command.
(FASTPATH Switching) #show lldp remote-device all
LLDP Remote Device Summary
Local
Interface RemID Chassis ID Port ID System
Name
------- ------- -------------------- ------------------ ------
------------
0/1
0/2
0/3
0/4
0/5
0/6
0/7 2 00:FC:E3:90:01:0F 00:FC:E3:90:01:11
0/7 3 00:FC:E3:90:01:0F 00:FC:E3:90:01:12
0/7 4 00:FC:E3:90:01:0F 00:FC:E3:90:01:13
0/7 5 00:FC:E3:90:01:0F 00:FC:E3:90:01:14
0/7 1 00:FC:E3:90:01:0F 00:FC:E3:90:03:11
0/7 6 00:FC:E3:90:01:0F 00:FC:E3:90:04:11
0/8
0/9
0/10
0/11
0/12
--More-- or (q)uit
Term Definition
Local Interface The interface that received the LLDPDU from the
remote device.
RemID An internal identifier to the switch to mark each
remote device to the system.
Chassis ID The ID that is sent by a remote device as part of the
LLDP message, it is usually a MAC address of the
device.
Port ID The port number that transmitted the LLDPDU.
System Name The system name of the remote device.