EPSON AcuLaser CX11/CX11F Revision B
TROUBLESHOOTING Printer 150
Engine Related (E)
Service Req E527 Deve Home Position Sensor Error
41 (p.209)
PWBA MCU could not receive signals output from Rotary Home Position Sensor within the specified time after rotation of Rotary
Developer.
Service Req E530 Humidity Sensor Error
50 (p.221)
When the Input from SENSOR HUM & TEMP is out of specification.
Service Req E533 Temp Sensor Error
49 (p.221)
SENSOR HUM & TEMP detected a temperature below -7°C or over 55°C.
Service Req E537 Fuser Fail
48 (p.219)
• Control Thermistor detected a temperature exceeding the specified temperature.
Safety Thermistor detected a temperature exceeding the specified temperature.
• The Control Thermistor did not detect a Ready even though the specified time elapsed from Main Lamp ON at Warm Up.
• The Main Lamp continues to stay lit even after time specified for the Main Lamp elapsed after the Control Thermistor detected a
Ready.
• The Control Thermistor detected a temperature below the specified temperature even after the specified time elapsed from Main
Lamp ON at Warm Up.
• The latch lever of FUSER ASSY is set incorrectly.
Service Req E542 IBT CLN Fail
52 (p.224)
SENSOR IBT RETRACT cannot detect Advance/Retract of CAM ASSY-IBT CL.
Service Req E547 Feed Motor Failure
51 (p.222)
DRIVE ASSY FEED (Feed Motor) of the Feeder is not rotating at the specified speed.
Service Req E998 Engine Communication Error
70 (p.243)
Acommunication error between the controller and the PWBA MCU via the video I/F occured
Table 3-11. List of Service Request
Class Panel Messaeg Description See FIP