EPSON AcuLaser CX11/CX11F Revision B
DISASSEMBLY AND ASSEMBLY ADF Section 527
4.4.5.2 GEAR PLATE, TRAY GEAR 24T, DOC. ADJUST L/R
REMOVAL
1. Remove the Scanner. (p306)
2. Remove the ADF Unit. (p481)
3. Remove the ADF COVER R. (p492)
4. Remove the PAPER GUIDE ASSY. (p526)
5. Remove the two screws (M3 x 8 mm, P-type, A-head) that secure the TRAY
COVER to the DOC. PAPER GUIDE.
6. Release the hook and remove TRAY GEAR 24T.
7. Release the hook and remove the two GEAR PLATEs.
8. Release the hook and remove the DOC.ADJUST L and R.
Figure 4-220. Removal of GEAR PLATE, TRAY GEAR 24T, DOC.ADJUST L/R
(1)
Figure 4-221. Removal of GEAR PLATE, TRAY GEAR 24T, DOC.ADJUST L/R
(2)
Figure 4-222. Removal of GEAR PLATE, TRAY GEAR 24T, DOC.ADJUST L/R
(3)
TRAY COVER
5)
DOC. PAPER GUIDE
GEAR PLATETRAY GEAR 24T
Hooks
DOC. ADJUST L
DOC. ADJUST R
DOC. PAPER GUIDE