EPSON AcuLaser CX11/CX11F Revision B
DISASSEMBLY AND ASSEMBLY Printer 456
4.2.12.14 MOTOR ASSY FEEDER
REMOVAL
1. Remove COVER LEFT 500. (p449)
2. Unclamp the clamp on DRIVE ASSY FEED, and remove the harness on MOTOR
ASSY FEEDER.
3. Disconnect connector (P/J446) from PWBA MOT.
4. Remove the 2 screws (silver, 6 mm) fastening MOTOR ASSY FEEDER to
DRIVE ASSY FEED.
5. Remove MOTOR ASSY FEEDER from DRIVE ASSY FEED.
REINSTALLATION
1. Attach MOTOR ASSY FEEDER to DRIVE ASSY FEED with the harness of
MOTOR ASSY FEEDER facing up.
2. Fasten MOTOR ASSY FEEDER to DRIVE ASSY FEED with the 2 screws
(silver, 6 mm).
3. Connect connector (P/J446) to PWBA MOT.
4. Fasten the harness on MOTOR ASSY FEEDER with the clamp on DRIVE ASSY
FEED.
5. Attach COVER LEFT 500. (p449)
Figure 4-133. Removal of MOTOR ASSY FEEDER
C A U T I O N
When performing the following work, pay attention to the
attachment direction of MOTOR ASSY FEEDER.
Table 4-22. Symptoms when the connector is loose
Connector
No.
Panel Indication Symptom
Error Caused by Connector
Disconnection
CN2
Ready Paper Jam
LC, G
Paper Jam ---