EPSON AcuLaser CX11/CX11F Revision B
APPENDIX Fax Unit System 648
COMMUNICATION CONTROL
Table 7-19. List of System Parameter (Communication Control)
Label
Maintenanc
e Code
User
Access
Internal
Address
Description Setting Value Default
Remark
s
Main Sub
COM_TX_ATT_LEVEL 300 006
---
0A0
Tone transmitting level
(decreasing amount from offset 0 dBM)
5 to 15 (-5 to -15dBm)
1step = -1dBm
Tone transmitting level = minus set dBm
-10 dBm
(10)
---
COM_MANTX_CNG 300 024
---
0A1
CNG transmitting at manual sending
Set whether send or not send the CNG signal when sending a fax
manually.
0 = Not send
1 = Send
Send
(1)
---
COM_RX_ATT_LEVEL 300 025
---
0A2
Receiving level
Set the tone level to be detected as an incoming fax.
0 = -43 dBm
1 = -38 dBm
2 = -33 dBm
3 = -48 dBm
-43 dBm
(0)
---
COM_CED_DETECT_TIME 310 006
---
0A3
CED detecting time
0 to 2550 ms (1 Step = 10 ms) 100 ms
(10)
---
COM_V34_SYM_RATE_MAX
310 007
---
0A4
Symbol speed maximum variation tolerance
This setting is enabled only when receiving a fax
0 = 2400 baud
1 = 2743 baud
2 = 2800 baud
3 = 3000 baud
4 = 3200 baud
5 = 3429 baud
3429 baud
(5)
---
COM_V34_BIT_RATE_MAX 310 008
---
0A5
Maximum bit speed
1 = 2400 bps
2 = 4800 bps
3 = 7200 bps
4 = 9600 bps
5 = 12000 bps
6 = 14400 bps
7 = 16800 bps
8 = 13200 bps
9 = 21600 bps
10 = 24000 bps
11 = 26400 bps
12 = 28800 bps
13 = 31200 bps
14 = 33600 bps
33600 bps
(14)
---