1299User Manual 1173.9163.02 ─ 62
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt.........................................................1306
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP......................................................... 1306
[SENSe<Ch>:]SEGMent<Seg>:INSert........................................................................... 1307
[SENSe<Ch>:]SEGMent<Seg>:INSert:SELect................................................................ 1309
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>:POWer[:LEVel].........................................1309
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>[:STATe]................................................... 1310
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol....................................................... 1310
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol:ALL.................................................1311
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol:CONTrol..........................................1312
[SENSe<Ch>:]SEGMent<Seg>:POWer[:LEVel]...............................................................1313
[SENSe<Ch>:]SEGMent:POWer[:LEVel]:CONTrol...........................................................1313
[SENSe<Ch>:]SEGMent<Seg>[:STATe]......................................................................... 1314
[SENSe<Ch>:]SEGMent<Seg>:SWEep:DWELl...............................................................1315
[SENSe<Ch>:]SEGMent<Seg>:SWEep:DWELl:CONTrol................................................. 1315
[SENSe<Ch>:]SEGMent<Seg>:SWEep:GENeration........................................................1316
[SENSe<Ch>:]SEGMent<Seg>:SWEep:POINts.............................................................. 1317
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME.................................................................1317
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME:CONTrol................................................... 1318
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME:SUM?....................................................... 1318
[SENSe<Ch>:]SEGMent<Seg>:ADD
Inserts a new sweep segment using default channel settings ("Insert New Segment").
The added segment covers the frequency interval between the maximum frequency of
the existing sweep segments and the stop frequency of the entire sweep range.
Tip: Use [SENSe<Ch>:]SEGMent<Seg>:INSert to create a segment with specific
channel settings.
Suffix:
<Ch>
.
Channel number
<Seg> Sweep segment number. Segment numbers must be sequential.
If n segments exist already, the added segment must have the
segment number n+1.
Example:
SEGM:INS 1MHZ, 1.5MHZ, 111, -21DBM, 0.5S, 0,
10KHZ
Create a sweep segment with a sweep range between 1.0 MHz
and 1.5 MHz.
SEGM2:ADD
Create a second sweep segment. The frequency range of the
second segment will be between 1.5 MHz and the maximum fre-
quency of the analyzer.
Usage: Event
Manual operation: See "Add / Insert / Delete / Delete All" on page 433
SCPI command reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ZNB Series and is the answer not in the manual?

R&S ZNB Series Specifications

General IconGeneral
BrandR&S
ModelZNB Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals