190 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
6 Root (:) Commands
Introduction to
Root (:)
Commands
Root level commands control many of the basic operations of the
instrument. These commands are always recognized by the parser if they
are prefixed with a colon, regardless of current command tree position.
After executing a root-level command, the parser is positioned at the root
of the command tree.
n/a :STATus? <display>
(see page 222)
{0 | 1}
<display> ::= {CHANnel<n> |
DIGital<d> | POD{1 | 2} | BUS{1 |
2} | FUNCtion | MATH | SBUS{1 |
2} | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<r> ::= 1 to (# ref waveforms) in
NR1 format
:STOP (see page 223) n/a n/a
n/a :TER? (see page 224) {0 | 1}
:VIEW <source> (see
page 225)
n/a <source> ::= {CHANnel<n> |
FUNCtion | MATH | SBUS{1 | 2} |
WMEMory<r>} for DSO models
<source> ::= {CHANnel<n> |
DIGital<d> | POD{1 | 2} | BUS{1 |
2} | FUNCtion | MATH | SBUS{1 |
2} | WMEMory<r>} for MSO models
<n> ::= 1 to (# analog channels)
in NR1 format
<d> ::= 0 to (# digital channels
- 1) in NR1 format
<r> ::= 1 to (# ref waveforms) in
NR1 format
Table 69 Root (:) Commands Summary (continued)
Command Query Options and Query Returns