556 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
24 :POWer Commands
:POWer:ONOFf:TEST
(see page 1138)
Command Syntax
:POWer:ONOFf:TEST {{0 | OFF} | {1 | ON}}
The :POWer:ONOFf:TEST command selects whether turn on or turn off
analysis is performed:
ON — Turn On — measures the time taken to get the output voltage of
the power supply after the input voltage is applied.
OFF — Turn Off — measures the time taken for the output voltage of
the power supply to turn off after the input voltage is removed.
Query Syntax
:POWer:ONOFf:TEST?
The :POWer:ONOFf:TEST query returns the selected test type.
Return Format
{0 | 1}
See Also ":POWer:ONOFf:APPLy" on page 553
":POWer:ONOFf:EXIT" on page 554
":POWer:ONOFf:NEXT" on page 555