516 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
22 :MTESt Commands
:MTESt:SCALe:BIND
(see page 1138)
Command Syntax
:MTESt:SCALe:BIND <on_off>
<on_off> ::= {{1 | ON} | {0 | OFF}}
The :MTESt:SCALe:BIND command enables or disables Bind 1 & 0 Levels
(Bind - 1 & 0 Levels for inverted masks) control:
• ON —
If the Bind 1 & 0 Levels control is enabled, the 1 Level and the 0 Level
controls track each other. Adjusting either the 1 Level or the 0 Level
control shifts the position of the mask up or down without changing its
size.
If the Bind - 1 & 0 Levels control is enabled, the - 1 Level and the 0
Level controls track each other. Adjusting either the - 1 Level or the 0
Level control shifts the position of the mask up or down without
changing its size.
• OFF —
If the Bind 1 & 0 Levels control is disabled, adjusting either the 1 Level
or the 0 Level control changes the vertical height of the mask.
If the Bind - 1 & 0 Levels control is disabled, adjusting either the - 1
Level or the 0 Level control changes the vertical height of the mask.
Query Syntax
:MTESt:SCALe:BIND?
The :MTESt:SCALe:BIND? query returns the value of the Bind 1&0 control
(Bind - 1&0 for inverted masks).
Return Format
<on_off><NL>
<on_off> ::= {1 | 0}
See Also • "Introduction to :MTESt Commands" on page 491
• ":MTESt:SCALe:X1" on page 517
• ":MTESt:SCALe:XDELta" on page 518
• ":MTESt:SCALe:Y1" on page 519
• ":MTESt:SCALe:Y2" on page 520