642 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
27 :SBUS<n> Commands
:SBUS<n>:A429:SIGNal
(see page 1138)
Command Syntax
:SBUS<n>:A429:SIGNal <signal>
<signal> ::= {A | B | DIFFerential}
The :SBUS<n>:A429:SIGNal command specifies the signal type:
• A — Line A (non- inverted).
• B — Line B (inverted).
• DIFFerential — Differential (A- B).
Query Syntax
:SBUS<n>:A429:SIGNal?
The :SBUS<n>:A429:SIGNal? query returns the current ARINC 429 signal
type setting.
Return Format
<signal><NL>
<signal> ::= {A | B | DIFF}
Errors • "- 241, Hardware missing" on page 1099
See Also • "Introduction to :SBUS<n> Commands" on page 629
• ":SBUS<n>:MODE" on page 633
• ":SBUS<n>:A429:FORMat" on page 641
• ":SBUS<n>:A429:SPEed" on page 644
• ":SBUS<n>:A429:SOURce" on page 643

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals