What's New 1
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 33
What's New in Version 2.20
New features in version 2.20 of the InfiniiVision 3000 X- Series oscilloscope
software are:
• Support for modulation of the waveform generator output.
• Support for controlling the optional DSOXDVM digital voltmeter analysis
feature
• Power measurements application modifications.
• Ability to turn reference waveform locations on or off and view their
status using the :VIEW, :BLANk, and :STATus commands.
More detailed descriptions of the new and changed commands appear
below.
New Commands
Command Description
:DVM Commands (see page 309) Commands for controlling the optional
DSOXDVM digital voltmeter analysis feature.
:MEASure:CPLoss (see page 474) Installs a power loss per cycle measurement on
screen or returns the measured value.
:POWer:SIGNals:CYCLes:HARMonics (see
page 565)
Specifies the number of cycles to include in the
current harmonics analysis.
:POWer:SIGNals:CYCLes:QUALity (see
page 566)
Specifies the number of cycles to include in the
power quality analysis.
:POWer:SIGNals:DURation:EFFiciency (see
page 567)
Specifies the duration of the efficiency
analysis.
:POWer:SIGNals:DURation:MODulation (see
page 568)
Specifies the duration of the modulation
analysis.
:POWer:SIGNals:DURation:ONOFf:OFF (see
page 569)
Specifies the duration of the turn off analysis.
:POWer:SIGNals:DURation:ONOFf:ON (see
page 570)
Specifies the duration of the turn on analysis.
:POWer:SIGNals:DURation:RIPPle (see
page 571)
Specifies the duration of the output ripple
analysis.
:POWer:SIGNals:DURation:TRANsient (see
page 572)
Specifies the duration of the transient
response analysis.
:POWer:SIGNals:VMAXimum:INRush (see
page 575)
Specifies the maximum expected input voltage
for inrush current analysis.
:POWer:SIGNals:VMAXimum:ONOFf:OFF (see
page 576)
Specifies the maximum expected input voltage
for turn off analysis.

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals