:POWer Commands 24
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 541
:POWer:HARMonics:LINE
(see page 1138)
Command Syntax
:POWer:HARMonics:LINE <frequency>
<frequency> ::= {F50 | F60 | F400}
The :POWer:HARMonics:LINE command specifies the line frequency setting
for the current carmonics analysis:
• F50 — 50 Hz.
• F60 — 60 Hz.
• F400 — 400 Hz.
Query Syntax
:POWer:HARMonics:LINE?
The :POWer:HARMonics:LINE query returns the line frequency setting.
Return Format
<frequency><NL>
<frequency> ::= {F50 | F60 | F400}
See Also • ":POWer:HARMonics:APPLy" on page 537
• ":POWer:HARMonics:DATA" on page 538
• ":POWer:HARMonics:DISPlay" on page 539
• ":POWer:HARMonics:FAILcount" on page 540
• ":POWer:HARMonics:POWerfactor" on page 542
• ":POWer:HARMonics:RUNCount" on page 543
• ":POWer:HARMonics:STANdard" on page 544
• ":POWer:HARMonics:STATus" on page 545
• ":POWer:HARMonics:THD" on page 546

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals