EasyManuals Logo

Agilent Technologies InfiniiVision 3000 X-Series Programmer's Guide

Agilent Technologies InfiniiVision 3000 X-Series
1282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1019 background imageLoading...
Page #1019 background image
:WGEN Commands 33
Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide 1019
:WGEN:MODulation:FUNCtion
(see page 1138)
Command Syntax
:WGEN:MODulation:FUNCtion <shape>
<shape> ::= {SINusoid | SQUare| RAMP}
The :WGEN:MODulation:FUNCtion command specifies the shape of the
modulating signal.
When the RAMP shape is selected, you can specify the amount of time per
cycle that the ramp waveform is rising with the
:WGEN:MODulation:FUNCtion:RAMP:SYMMetry command.
This command applies to AM and FM modulation. (The FSK modulation
signal is a square wave shape.)
Query Syntax
:WGEN:MODulation:FUNCtion?
The :WGEN:MODulation:FUNCtion? query returns the specified modulating
signal shape.
Return Format
<shape><NL>
<shape> ::= {SIN | SQU| RAMP}
See Also • ":WGEN:MODulation:AM:DEPTh" on page 1013
• ":WGEN:MODulation:AM:FREQuency" on page 1014
• ":WGEN:MODulation:FM:DEViation" on page 1015
• ":WGEN:MODulation:FM:FREQuency" on page 1016
• ":WGEN:MODulation:FSKey:FREQuency" on page 1017
• ":WGEN:MODulation:FSKey:RATE" on page 1018
• ":WGEN:MODulation:FUNCtion:RAMP:SYMMetry" on page 1020
• ":WGEN:MODulation:STATe" on page 1022
• ":WGEN:MODulation:TYPE" on page 1023

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 3000 X-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 3000 X-Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 3000 X-Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 3000 X-Series
CategoryTest Equipment
LanguageEnglish

Related product manuals