372 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
17 :HARDcopy Commands
:HARDcopy:PRINter:LIST
(see page 1138)
Query Syntax
:HARDcopy:PRINter:LIST?
The :HARDcopy:PRINter:LIST? query returns a list of available printers.
The list can be empty.
Return Format
<list><NL>
<list> ::= [<printer_spec>] ... [printer_spec>]
<printer_spec> ::= "<index>,<active>,<name>;"
<index> ::= integer index of printer
<active> ::= {Y | N}
<name> ::= name of printer (for example "DESKJET 950C")
See Also • "Introduction to :HARDcopy Commands" on page 358
• ":HARDcopy:APRinter" on page 360
• ":HARDcopy:STARt" on page 373