892 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
31 :TRIGger Commands
:TRIGger:DELay:TDELay:TIME
(see page 1138)
Command Syntax
:TRIGger:DELay:TDELay:TIME <time_value>
<time_value> ::= time in seconds in NR3 format
The :TRIGger:DELay:TDELay:TIME command sets the delay time between
the arming edge and the trigger edge in the Edge Then Edge trigger. The
time is in seconds and must be from 4 ns to 10 s.
Query Syntax
:TRIGger:DELay:TDELay:TIME?
The :TRIGger:DELay:TDELay:TIME? query returns current delay time
setting.
Return Format
<time value><NL>
<time_value> ::= time in seconds in NR3 format
See Also • "Introduction to :TRIGger Commands" on page 877