EPSON AcuLaser CX11/CX11F Revision B
TROUBLESHOOTING Printer 185
23
Continuity check of HARNESS-ASSY P/H2
Disconnect P/J603.
Do all of the wiring below have normal
continuity?
P603-1P202-2
P603-2P202-1
Go to Step [24]. Replace
HARNESS-
ASSY P/H2.
24
Check of resistance value of CLUTCH ASSY
PRE REGI
Disconnect P/J202.
The winding resistance between the terminals
of CLUTCH ASSY PRE REGI
is 144 ± 10% (20°C)?
Go to Step [20].
Replace
CLUTCH ASSY
PRE REGI.
(p.363)
Step Check Yes No