Command Manual - HWPing
Quidway S3900 Series Ethernet Switches-Release 1510 Chapter 1 HWPing Commands
Huawei Technologies Proprietary
1-8
Description
Use the test-enable command to execute an HWPing test.
Use the undo test-enable command to disable an HWPing test.
Note:
After you execute the test-enable command, the system does not display the test
result. You may view the test result information by executing the display hwping
command.
Related command: display hwping.
Example
# Execute the HWPing test defined by the test group “administrator-icmp”.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] hwping administrator icmp
[Quidway-hwping-administrator-icmp] test-enable
1.1.8 test-type
Syntax
test-type type
View
HWPing test group view
Parameter
type: Test type.
Description
Use the test-type command to configure the type of the test.
Currently the system only supports ICMP test.
Example
# Set the test type of the “administrator-icmp” test group to ICMP.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] hwping administrator icmp

Table of Contents

Other manuals for Huawei Quidway S3900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3900 Series and is the answer not in the manual?

Huawei Quidway S3900 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3900 Series
CategorySwitch
LanguageEnglish

Related product manuals