Example
# Clear NDP statistics.
<Quidway> reset ndp statistics
1.2 NTDP Configuration Commands
1.2.1 display ntdp
Syntax
display ntdp
View
Any view
Parameter
None
Description
Use the display ntdp command to display the global NTDP information. The
information includes the range (in hop count) within which topology information is
collected, the interval to collect topology information (the NTDP timer), the delay time
for a device to forward topology-collection requests, the delay time for a
topology-collection request to be forwarded through a port, and the time cost during the
last topology collection.
Example
# Display the global NTDP information.
<Quidway> display ntdp
NTDP is running.
Hops : 4
Timer : 0 min(disable)
Hop Delay : 100 ms
Port Delay: 10 ms
Last collection total time: 92ms
Table 1-2 Description on the fields of the display ntdp command
Field Description
NTDP is running. NTDP is enabled globally on the local device.
Hops Hop count for topology collection

Table of Contents

Other manuals for Huawei Quidway S3900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3900 Series and is the answer not in the manual?

Huawei Quidway S3900 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3900 Series
CategorySwitch
LanguageEnglish

Related product manuals