Command Manual – IRF Fabric
Quidway S3900 Series Ethernet Switches-Release 1510 Chapter 1 IRF Fabric Commands
Huawei Technologies Proprietary
1-3
5 000f-cbb7-2142 10 /Right 1 A
*6 000f-cbb7-3264 10 Left/ 1 A
7 000f-cbb7-2260 10 /Right 1 A
8 000f-cbb7-2734 10 Left/ 1 A
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] change unit-id 1 to 2
The unit 2 already exists in fabric.
Continue? [Y/N] y
[Quidway]
%Apr 2 00:48:34:574 2000 Quidway FTM/3/DDPFLA:- 6 -Change unitid successful,
un
it 4 saved UnitID(4) in flash!
<Quidway>display ftm topology-database
Total number of units in fabric : 2, My Unit ID : 4
UID CPU-Mac Priority Stack-Port Board-ID A/M
1 00e0-fc00-5002 10 /Right 1 A
2 00e0-fc03-5132 10 Left/ 1 A
3 00e0-fc04-5252 10 /Right 1 A
*4 000f-cbb7-3264 5 Left/ 1 A
5 000f-cbb7-2142 10 /Right 1 A
6 00e0-fc05-8922 10 Left/ 1 A
7 000f-cbb7-2260 10 /Right 1 A
8 000f-cbb7-2734 10 Left/ 1 A
From the above example, you can see the original unit ID of the device with MAC
address 000f-cbb7-3264 is 6. After the configuration, this unit ID changes to 4, and the
priority of the device changes to 5.
1.1.3 display ftm
Syntax
display ftm{ information | topology-database }
View
System view
Parameter
Information: Displays the FTM protocol information, including DDP status, unit ID, link
status of the fabric, status of the fabric port, and DDP packets statistics.
topology-database: Displays the topology database information of the fabric.