Command Manual – Routing Protocol
Quidway S3900 Series Ethernet Switches-Release 1510 Chapter 2 RIP Configuration Commands
Huawei Technologies Proprietary
2-22
Description
Use the timers command to modify the values of the three RIP timers: Period Update,
Timeout, and Garbage-collection (which is usually set to a value four times that of the
Period Update timer).
Use the undo timers command to restore the default settings.
By default, the Period Update, Timeout, and Garbage-collection timers are 30 seconds,
180 seconds, and 120 seconds, respectively.
Generally, it is regarded that the value of the Garbage-collection timer is fixed at four
times that of the Period Update timer. Adjusting the Period Update timer will affect the
Garbage-collection timer.
The modification of RIP timers is validated immediately.
Related command: display rip.
Example
# Set the values of the Period Update timer and the Timeout timer of RIP to 10 seconds
and 30 seconds respectively.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] rip
[Quidway-rip] timers update 10 timeout 30
2.1.25 traffic-share-across-interface
Syntax
traffic-share-across-interface
undo traffic-share-across-interface
View
RIP view
Parameter
None
Description
Use the traffic-share-across-interface command to enable traffic sharing across RIP
interfaces, so as to distribute traffic evenly over equal-cost routes across the interfaces
on a router.
Use the undo traffic-share-across-interface command to cancel traffic sharing.