1.3.12 reset stop-accounting-buffer
Syntax
reset stop-accounting-buffer { hwtacacs-scheme hwtacacs-scheme-name |
session-id session-id | time-range start-time stop-time | user-name user-name }
View
User view
Parameter
hwtacacs-scheme hwtacacs-scheme-name: Configures to delete the
stop-accounting requests from the buffer according to the specified HWTACACS
scheme name. The hwtacacs-scheme-name specifies the HWTACACS scheme
name with a character string of up to 32 characters, excluding forward slashes (/),
colons (:), asterisks (*), question marks (?), less-than signs (<), and greater-than
signs (>).
session-id session-id: Displays information on buffered stop-accounting requests
according to the session ID specified by session-id, a character string of up to 50
characters.
time-range start-time stop-time: Displays information on buffered stop-accounting
requests according to the request time, where, start-time is the start time of the
stop-accounting request; stop-time is the end time of stop-accounting request. This
argument is in the format hh:mm:ss - mm/dd/yyyy or hh:mm:ss-yyyy/mm/dd and is
used to display the buffered stop-accounting requests from the start time to the end
time.
user-name user-name: Displays information on buffered stop-accounting requests
according to the user name specified by user-name, a character string of up to 80
characters, excluding forward slashes (/), colons (:), asterisks (*), question marks (?),
less-than signs (<), and greater-than signs (>). Moreover, “@” can appear no more
than once, and the user name (the part before “@”, the user ID) can not exceed 55
characters; the domain name (the rest part after “@”) cannot exceed 24 characters.
Description
Use the reset stop-accounting-buffer command to clear the stop-accounting
requests that have no response and are buffered on the switch.
Related command: stop-accounting-buffer enable, retry stop-accounting,
display stop-accounting-buffer.
Example
# Delete the buffered stop-accounting requests that are according to the HWTACACS
scheme “hwt1”.

Table of Contents

Other manuals for Huawei Quidway S3900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3900 Series and is the answer not in the manual?

Huawei Quidway S3900 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3900 Series
CategorySwitch
LanguageEnglish

Related product manuals