Command Manual – PoE & PoE Profile
Quidway S3900 Series Ethernet Switches-Release 1510 Chapter 1 PoE Configuration Commands
Huawei Technologies Proprietary
1-4
Field Description
ENABLE PoE enabled/disabled status on the port
MODE
PoE mode on the port:
z signal: PoE through the signal cable
z spare: PoE through the spare cable
PRIORITY
PoE priority of the port:
z critical: Highest
z high: High
z low: Low
STATUS
PoE status on the port:
z user command set port to off: PoE to the port is
turned off by the user
z Standard PD was detected: A standard PD is
detected
z PD detection is in process: PDs are being
detected
1.1.2 display poe interface power
Syntax
display poe interface power [ interface-type interface-number ]
View
Any view
Parameter
interface-type interface-number: Port on the switch. Refer to Command Manual – Port
for details.
Description
Use the display poe interface power command to view the power information of a
specific port of the switch. If the interface-type interface-number argument is not
specified, the command displays the power information of all ports of the switch.
Example
# Display the power information of Ethernet 1/0/10.
<Quidway> display poe interface power Ethernet1/0/10
Port power :12400 mW
# Display the power information of all ports.
<Quidway> display poe interface power
PORT INDEX POWER (mW) PORT INDEX POWER (mW)

Table of Contents

Other manuals for Huawei Quidway S3900 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S3900 Series and is the answer not in the manual?

Huawei Quidway S3900 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S3900 Series
CategorySwitch
LanguageEnglish

Related product manuals