Command Manual – Port Basic Configuration
Quidway S3900 Series Ethernet Switches-Release 1510
Chapter 1 Port Basic Configuration
Commands
Huawei Technologies Proprietary
1-15
View
Ethernet port view
Parameter
Interval: Interval (in seconds) to perform statistics on port information. This argument
ranges from 5 to 300 (in step of 5) and is 300 by default.
Description
Use the flow-interval command to set the interval to perform statistics on port
information.
Use the undo flow-interval command to restore the default interval.
By default, this interval is 300 seconds.
When you use the display interface interface-type interface-number command to
display the information of a port, the system performs statistical analysis on the traffic
flow passing through the port during the specified interval and displays the average
rates in the interval. For example, if you set the interval to 100 seconds, the displayed
information is as follows:
Last 100 seconds input: 0 packets/sec 0 bytes/sec
Last 100 seconds output: 0 packets/sec 0 bytes/sec
Related command: display interface.
Example
# Set the interval to perform statistics on the Ethernet1/0/1 port to 100 seconds.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] interface ethernet 1/0/1
[Quidway-Ethernet1/0/1] flow-interval 100
1.1.14 giant-frame statistics enable
Syntax
giant-frame statistics enable
undo giant-frame statistics enabl
View
System view
Parameter
None