Command Manual - Getting Started
Quidway S6500 Series Ethernet Switches Chapter 1 Logging in Ethernet Switch Commands
Huawei Technologies Proprietary
1-14
Parameter
seconds: Specifies the timer answer in seconds, ranging from 1 to 60.The default value
is 30s.
Description
Using modem timer answer command, you can configure the timer answer from
off-hook to carrier detected when establishing the call in connection. Using undo
modem timer answer command, you can restore the default timeout value.
This command can only be performed in AUX user interface view.
Example
# Set the timer answer of AUX 0 to 45s.
[Quidway-ui-aux0] modem timer answer 45
1.1.18 parity
Syntax
parity { even | mark | none | odd | space }
undo parity
View
User interface view
Parameter
even: Configures to perform even parity.
mark: Configures to perform mark parity.
none: Configures not to perform parity.
odd: Configures to perform odd parity.
space: Configures to perform space parity.
Description
Using parity command, you can configure the parity mode on AUX (Console) port.
Using undo parity command, you can restore the default parity mode.
This command can only be performed in AUX user interface view.
By default, the mode is set to none.
Example
# Set mark parity on the AUX (Console) port.
[Quidway-ui-aux0] parity mark