Command Manual - Port
Quidway S6500 Series Ethernet Switches Chapter 1 Ethernet Port Configuration Commands
Huawei Technologies Proprietary
1-12
Parameter
time: Specifies the interval of monitoring external loopback conditions of the port. It
ranges from 5 to 300, measured in seconds. By default, the interval is 30 seconds.
Description
Using loopback-detection interval-time command, you can configure detection
interval for the external loopback condition of each port. Using undo
loopback-detection interval-time command, you can restore the default interval.
For the related command, see display loopback-detection.
Example
# Configure the detection interval for the external loopback condition of each port to 10
seconds.
<Quidway> system-view
System View: return to User View with Ctrl+Z.
[Quidway] loopback-detection interval-time 10
[Quidway]
1.1.13 loopback-detection per-vlan enable
Syntax
loopback-detection per-vlan enable
undo loopback-detection per-vlan enable
View
Ethernet port view
Parameter
none
Description
Using the loopback-detection per-vlan enable command, you can configure that the
system performs loopback detection to all VLANs on Trunk and Hybrid ports. Using the
undo loopback-detection per-vlan enable command, you can configure that the
system only performs loopback detection to the default VLANs on the port.
By default, the system performs loopback detection to the default VLAN on Trunk and
Hybrid ports.