Command Manual - PoE
Quidway S6500 Series Ethernet Switches
Chapter 2 PoE PSU Supervision Configuration
Commands
Huawei Technologies Proprietary
2-3
Table 2-2 Description on the fields of the display poe-power alarm command
Field Description
NORMAL: No alarm.
NOTLINK: The PSU is not linked (the controller fails to
communicate with this PSU or the PSU is not inserted). You
can clear the error by power-cycling the PSU or inserting a
PSU).
INERROR: PSU input error (AC input undervoltage). Restoring
the normal AC input can clear the error.
OUTERROR: PSU output error (No normal DC output from the
PSU).
HIGHVOL: Overvoltage on the PSU (the PSU is shut down).
HIGHTEP: It is overheated in the PSU.
FANERROR: The fan is faulty.
CLOSE: The PSU is shut down.
CURLIMIT: The current of the PSU is limited.
PSU 1 alarm:
(alarm
information about
PoE PSU1)
Absent: The PSU is absent.
2.1.3 display poe-power dc-output state
Syntax
display poe-power dc-output state
View
Any view
Parameter
None
Description
Use the display poe-power dc-output state command to display the DC output state
of the in-use PoE PSUs.
Example
# Display the DC output states of the in-use PoE PSUs.
<Quidway> display poe-power dc-output state
DC Output State : Normal

Table of Contents

Other manuals for Huawei Quidway S6500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S6500 Series and is the answer not in the manual?

Huawei Quidway S6500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S6500 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals