Command Manual - PoE
Quidway S6500 Series Ethernet Switches
Chapter 2 PoE PSU Supervision Configuration
Commands
Huawei Technologies Proprietary
2-3
Table 2-2 Description on the fields of the display poe-power alarm command
Field Description
NORMAL: No alarm.
NOTLINK: The PSU is not linked (the controller fails to
communicate with this PSU or the PSU is not inserted). You
can clear the error by power-cycling the PSU or inserting a
PSU).
INERROR: PSU input error (AC input undervoltage). Restoring
the normal AC input can clear the error.
OUTERROR: PSU output error (No normal DC output from the
PSU).
HIGHVOL: Overvoltage on the PSU (the PSU is shut down).
HIGHTEP: It is overheated in the PSU.
FANERROR: The fan is faulty.
CLOSE: The PSU is shut down.
CURLIMIT: The current of the PSU is limited.
PSU 1 alarm:
(alarm
information about
PoE PSU1)
Absent: The PSU is absent.
2.1.3 display poe-power dc-output state
Syntax
display poe-power dc-output state
View
Any view
Parameter
None
Description
Use the display poe-power dc-output state command to display the DC output state
of the in-use PoE PSUs.
Example
# Display the DC output states of the in-use PoE PSUs.
<Quidway> display poe-power dc-output state
DC Output State : Normal