Command Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 6 RMON Configuration Commands
Huawei Technologies Proprietary
6-2
Field Description
Variable formula The alarm variable value of the node.
Sampling interval The interval of sampling the value.
Rising threshold
Rising threshold. When sampling value rises from normal
value to this threshold, rising threshold alarm will be
triggered.
Falling threshold
Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm will be
triggered.
When startup
enables
Enable the first trigger.
risingOrFallingAlarm
The type of the first alarm: Specifies to alarm when
exceeding the rising threshold or the falling threshold.
Latest value The value of the latest sampling.
6.1.2 display rmon event
Syntax
display rmon event [ event-table-entry ]
View
Any view
Parameter
event-table-entry: Entry index of event table.
Description
Using display rmon event command, you can view RMON events.
The display includes event index in event table, owner of the event, description to the
event, action caused by event (log or alarm information), and occurrence time of the
latest event (counted on system initiate/boot time in centiseconds).
For the related commands, see rmon event.
Example
# Show the RMON event.
<Quidway> display rmon event
Event table 1 owned by abc is VALID.
Description: null.
Will cause log-trap when triggered, last triggered at 0days 00h:02m:27s.